The Advanced Energy CoolX1000 series, including the CX10S-AGDHBC-P-A-DK00000, provides a fanless 1000W modular power supply solution. This specific model is an enclosed, chassis mount AC/DC converter delivering 905W of power with a 24V output and 3A current.
Key electrical specifications include a high efficiency of 93% and a wide operating temperature range from -40°C to 85°C. The unit features adjustable output, PMBus communication for monitoring and control, remote sense, standby output, and universal input.
With dimensions of 259.5mm x 164.0mm x 40.6mm, it is designed for ITE (Commercial) and Medical applications. Compliance includes standards like IEC60601-1, IEC60950-1, and IEC62368-1, with approval from agencies such as CSA, EN, IEC, and UL. The fanless design eliminates acoustic noise and vibrations, making it suitable for sensitive environments.
Reliability is enhanced by an MTBF of over 2,900,000 hours and input surge protection up to 4 kV. The power supply is safety approved for operation up to 5000m altitude.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The output voltage is 24V.
The maximum output current is 3 A.
The power rating is 905W.
The operating temperature range is -40°C to 85°C.
Yes, it features PMBus monitoring and control capability.
The dimensions are 259.5mm x 164.0mm x 40.6mm.
It complies with IEC60601-1 3rd edition and IEC60601-1-2 4th edition (EMC).