| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
5,245 pcs
|
5245 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Control Features | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Input Voltage | |
| Isolation Voltage (Minimum @ dc) | |
| Isolation Voltage (Minimum @ transient (1 minute) | |
| Length | |
| Maximum Input Current | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current (Nominal @ Output 1) | |
| Output Current (Nominal @ Output 2) | |
| Output Current (Nominal @ Output 3) | |
| Output Voltage (Nominal @ Output 1) | |
| Output Voltage (Nominal @ Output 2) | |
| Output Voltage (Nominal @ Output 3) | |
| Package / Case | |
| Power (Output) | |
| Power (Watts) | |
| Storage Temperature | |
| Termination Style | |
| Type | |
| Voltage | |
| Width |
The CC025ABK-M is a triple-output isolated DC-DC converter module from ABB Power Electronics, part of the CC025 Triple-Output Series. It delivers a total output power of 25W from a nominal 28V (18-36V) input. The main output provides 5V at 5A, while the auxiliary outputs offer 12V and -12V at 1A each. The module achieves typical efficiency of 82% and provides 500Vdc isolation (850V transient).
The converter is housed in a compact 10-DIP through-hole package measuring 71.1mm x 61.0mm x 12.7mm. It features remote on/off control (positive logic), overcurrent protection (OCP), and overvoltage protection (OVP). The metal case provides good thermal performance, with an operating case temperature range of -40°C to 100°C and storage from -55°C to 125°C.
Design applications include distributed power architectures, telecommunications equipment, and commercial ITE (Information Technology Equipment) systems. The module is designed to meet UL, CSA, and VDE safety standards and complies with FCC and CISPR Class A radiated emissions limits. The industry-standard pinout simplifies integration into existing designs.
18-36 Vdc, with typical 28 V.
10-DIP through-hole module.
-40°C to 100°C case temperature.
Yes, RoHS3 compliant (unverified).
5V at 5A, 12V at 1A, -12V at 1A.
500 Vdc minimum, 850 V transient.
Remote on/off, overcurrent protection (OCP), overvoltage protection (OVP).