| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
669 pcs
|
669 pcs | On Request | 1 | On Request | On Request | 01+ | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Industrial Grade | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Power (Watts) | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Weight | |
| Width |
The BXA3-48S05 is a 3W isolated DC-DC converter from Artesyn Embedded Power's BXA3 series. It provides a single 5V output at 500mA from a nominal 48V input (36-75V range). It features continuous short circuit protection and overvoltage protection.
Electrical characteristics include 76% typical efficiency, line and load regulation of ±2.5%, output voltage accuracy of ±1%, and ripple and noise of 60mV pk-pk and 15mV rms. Switching frequency varies from 200kHz to 1MHz. Isolation voltage is 500VDC.
The converter operates over -25°C to +105°C and is housed in a 24-DIP module (600 mil, 10 leads) with through-hole mounting. Dimensions are 31.8mm x 20.3mm x 12.7mm, weight 15g. Material flammability rating is UL94 V-0. MTBF is 800,000 hours per MIL-HDBK-217F.
Safety approvals include VDE0805, EN60950, IEC950, UL1950, and CSA C22.2 No. 950. RoHS compliance is claimed but unverified. This variant does not include an internal Pi filter (available with -F suffix).
| Qty | Low | High |
|---|---|---|
| 200+ | $45.83 | $45.83 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The input voltage range is 36V to 75V DC, with a nominal input of 48V.
It comes in a 24-DIP Module (600 mil, 10 leads) with through-hole mounting.
-25°C to +105°C.
RoHS compliance is claimed as RoHS3 Compliant, but this is unverified and has conflicting sources.
3W.
Yes, continuous short circuit protection with automatic recovery.
VDE0805, EN60950, IEC950, UL1950, CSA C22.2 No. 950.