A0723076 The Artesyn Embedded Power A0723076 is a circuit breaker designed for use with the MS3500 system. It offers adjustable DC output voltage and power factor correction.
Mfr Part #:

A0723076

Mfr Name: Artesyn Embedded Power
Artesyn Embedded Power
The Artesyn Embedded Power A0723076 is a circuit breaker designed for use with the MS3500 system. It offers adjustable DC output voltage and power factor correction.
Stock on Request

A0723076 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Accessory Type
For Use With
SVHC Present

A0723076 Description

Short technical summary and product information.

The Artesyn Embedded Power A0723076 is a specialized circuit breaker accessory designed for integration with the MS3500 power system. This component ensures reliable operation and protection within the power supply infrastructure.

 

Key electrical specifications include an adjustable DC output voltage range from 48 to 55.5VDC, with options for 110VAC or 220VAC input systems. The unit features power factor correction, achieving a nominal power factor of 0.99 at 50-100% load. It also provides adjustable battery charge control from 2A to 20A and includes 10 fuse positions, each rated up to 15A, along with up to five breaker positions for distribution.

 

Environmental and safety compliance are critical for this component. It meets EMC/EMI standards including FCC Class B and CISPR Class B, ESD requirements per Bellcore TR-NWT-001089, and shock and vibration standards per Bellcore TR-NWT-000063. Fire resistance is rated UL94VO, and it meets IEEE C62.41-1991 for voltage surge protection. Safety certifications include UL 1950, UL1801, and CSA C22.2 No.

 

The operating temperature range is -40°C to +50°C with natural convection cooling, extending to -40°C to +65°C with forced air cooling. Humidity tolerance is 0 to 95% RH non-condensing. The compact dimensions are 21.5"W x 5.25"H x 14"D (550 x 133 x 300mm).

A0723076 Quick Information

Product Type: Circuit Breaker
Canonical Name: Artesyn Embedded Power A0723076 Circuit Breaker for MS3500
Subcategory: Accessories

A0723076 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

A0723076 Features

  • Circuit breaker for MS3500 system.
  • Adjustable DC output voltage 48-55.5VDC.
  • Power factor correction included.
  • Wide operating temperature range.
  • Meets FCC Class B and UL safety standards.

A0723076 Applications

  • Protects MS3500 power systems.
  • Suitable for industrial environments.
  • Ensures reliable power delivery.
  • Used in demanding applications.

A0723076 FAQs

32 frequently asked questions generated from this part’s specifications.
What is the adjustable DC output voltage range for the A0723076?

The DC output voltage is user selectable from 48 to 55.5 VDC.

What is the maximum output power at 110VAC input?

The maximum output power at 110VAC input is 1750W.

What is the maximum output power at 220VAC input?

The maximum output power at 220VAC input is 3500W.

What is the input voltage range for systems with 250W rectifiers?

The input voltage range for systems with 250W rectifiers is 96 - 132 VAC.

What is the input voltage range for systems with 500W rectifiers?

The input voltage range for systems with 500W rectifiers is 176 - 264 VAC.

What is the operating frequency range?

The operating frequency range is 45 - 65 Hz.

What is the typical efficiency?

The efficiency is greater than 86% at 50-100% output load.

What is the power factor?

The power factor is 0.99 at 50-100% output load.

What is the total harmonic distortion?

The total harmonic distortion is less than 5%.

What are the load/line and load/line/temperature voltage regulation limits?

Load/line voltage regulation is +/- 0.5%, and load/line/temperature regulation is +/- 1.0%.

What is the dynamic response to load step changes?

The dynamic response is +/- 5% for 10% to 90% or 90% to 10% load step changes.

What is the power limit tolerance?

The power limit tolerance is 102.5 +/- 2.5% of rated power at output voltages above 42VDC.

What is the hold-up time?

The hold-up time is 30 ms, during which the output voltage remains above -42V.

What is the voice frequency noise level?

The voice frequency noise is less than 55 dBmC.

What is the high frequency noise level?

The high frequency noise is less than 250 mV rms.

What is the operating temperature range with natural convection cooling?

The operating temperature range with natural convection cooling is -40°C to +50°C.

What is the operating temperature range with forced air cooling?

The operating temperature range with forced air cooling is -40°C to +65°C.

What is the humidity range?

The humidity range is 0 to 95% RH, non-condensing.

What is the acoustic noise level?

The acoustic noise level is less than 65dB for the full system including rectifiers and fan unit.

What are the dimensions of the unit?

The dimensions are 21.5"W x 5.25"H x 14"D (550 x 133 x 300mm).

What EMC/EMI standards does this component meet?

It meets FCC Class B and CISPR Class B for digital devices, and Bellcore GR-1089-CORE.

What ESD standard does it comply with?

It complies with Bellcore TR-NWT-001089.

What shock and vibration standard does it meet?

It meets Bellcore TR-NWT-000063.

What is the fire resistance rating?

The fire resistance rating is UL94VO.

Does it meet voltage surge protection standards?

Yes, it meets IEEE C62.41-1991 for voltage surge protection.

What safety standards are met?

It meets UL 1950, UL1801, and CSA C22.2 No.

What is the maximum adjustable temperature compensation?

The maximum adjustable temperature compensation is 144 mV/°C.

What is the maximum adjustable low voltage disconnect setting?

The maximum adjustable low voltage disconnect setting is 47 V DC.

What is the adjustable battery charge control range?

The adjustable battery charge control range is 2A to 20A.

How many fuse positions are available for distribution?

There are 10 fuse positions available, each up to 15A.

How many breakers can be installed?

Up to five breakers can be installed.

What cooling methods are supported?

Both natural convection and forced air cooling are supported.

Home