The E-T-A 1658-G41-02-P10-055844-30A is a thermal overcurrent circuit breaker with a manual reset mechanism and a cycling trip-free design. It is approved to UL, CSA, VDE, and EN 60934 standards, meeting international requirements.
This single-pole breaker has a current rating of 30A and can operate at up to 240V AC or 28V DC. It features blade terminals for connection and is designed for panel mounting. The breaker offers a high interrupting capacity, rated at 200A for 8-30A ranges and 2500A for DC 32V.
Typical applications for this cost-effective design include battery chargers, consumer products, power supplies, and motors. It operates within an ambient temperature range of -20°C to +60°C, with a maximum of +40°C for current ratings up to 7A. The device is protected against dust and water ingress with an IP40 rating for the operating area.
Environmental testing includes resistance to vibration up to 8g, shock up to 30g, 96-hour salt mist corrosion, and 240-hour humidity exposure. The breaker has a mass of approximately 16g and is built with no exposed metal parts that could become current-carrying.
The voltage rating is 240V AC and 28V DC.
The current rating is 30A.
It is designed for panel mounting.
The ambient temperature range is -20°C to +60°C, with a maximum of +40°C for current ratings up to 7A.
The interrupting capacity (Icn) is 180A for 5-7A and 200A for 8-30A. For UL/EN, it is 2,000A (AC 240V/DC 28V) and 2,500A (DC 32V).