| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Failure Rate | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
This E-T-A 1658-G41-09-S83-055800-30A is a thermal overcurrent circuit breaker designed for reliable circuit protection. It operates with a 30A current rating and supports up to 240V AC or 28V DC.
The breaker features a manual reset with a cycling trip-free mechanism, making it suitable for applications requiring manual intervention after a fault. Its panel mount design facilitates easy integration into various systems.
Key electrical specifications include an interrupting capacity of up to 200A (Icn) and 2,500A (UL 1077/EN 60934 PC1) under specific conditions. The device operates within an ambient temperature range of -20°C to +60°C, with a maximum of +40°C for currents up to 7A.
Typical applications for this circuit breaker include battery chargers, consumer products, power supplies, and motors. It meets international requirements and is approved by UL, CSA, VDE, and EN 60934 (IEC 60934).
It is rated for 240V AC and 28V DC.
It uses a panel mount configuration with a push-to-reset actuator.
The device operates reliably between -20°C and +60°C.
It provides an interrupting capacity of 2,000A under UL 1077 and EN 60934 PC1 standards.
The operating area has an IP40 rating while the terminal area is IP00.