The Coilcraft Z9260-A is a flyback transformer specifically developed for use in flyback power supplies utilizing the ON Semiconductor NCP1200 PWM Current-Mode Controller. It is designed for universal input voltage ranges of 85-265 Vac.
Key electrical specifications include a nominal inductance of 0.7 mH (measured at 10 kHz, 0.1 Vrms, 0 Adc) and a maximum leakage inductance of 26 µH (tested at 100 kHz, 0.1 Vrms). The transformer offers a high isolation voltage of 2000 Vrms between primary and secondary windings. It has a primary to secondary turns ratio of 1:0.164 and is rated for an output of 16 V at 4.2 A.
Mechanical dimensions for the Z9260-A are 1.45 inches in length, 1.45 inches in width, and 1.17 inches in height. The operating temperature range is -40°C to +85°C. This transformer is supplied in trays of 25 units.
Coilcraft also offers custom engineering services for transformers tailored to specific requirements. For free evaluation samples, contact Coilcraft or visit their website.
The primary inductance is 0.7 mH, measured at 10 kHz, 0.1 Vrms, 0 Adc.
The maximum leakage inductance is 26 µH, tested at 100 kHz, 0.1 Vrms.
The maximum DCR is 0.261 Ohms.
The isolation voltage is 2000 Vrms.
The operating temperature range is -40°C to +85°C.
The primary to secondary turns ratio is 1:0.164, and the primary to auxiliary turns ratio is 1:0.15.
The standard package is 25 units per tray.