The Telemecanique XCSPA592 is a compact safety switch designed for reliable operation in industrial environments. It features a durable plastic construction and a key-operated turret head for actuator engagement.
This switch is equipped with 1 Normally Closed (NC) and 1 Normally Open (NO) contact configuration, utilizing a slow-break, break-before-make contact operation. The electrical connection is made via terminals with a clamping capacity of 1 x 0.5 to 2 x 1.5 mm², suitable for use with or without cable ends. It has a single entry tapped for M16 x 1.5 cable, accommodating cable outer diameters from 7 to 10 mm.
Designed for safety applications, the XCSPA592 offers double insulation and positive opening on its NC contact. It can achieve safety levels up to Category 4, PL = e, and SIL 3 when integrated with appropriate monitoring systems. The switch has a mechanical durability of 1,000,000 cycles and operates within an ambient temperature range of -25 to 70 °C.
Compliance with various international standards including IEC 60947-5-1, CSA C22.2 No 14, ISO 12100, EN 1088/ISO 14119, IEC 60204-1, and UL 508 is noted. The switch is certified by CSA and UL.
| Qty | Low | High |
|---|---|---|
| 1+ | $1.16 | $1.16 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The Telemecanique XCSPA592 safety switch has 1 Normally Closed (NC) and 1 Normally Open (NO) contact configuration.
The contact operation is slow-break, break before make.
The cable entry is tapped for M16 x 1.5.
The rated operational current is 6 A at 120 V AC-15 (A300) and 3 A at 240 V AC-15 (A300). For DC-13, it is 0.55 A at 125 V (Q300) and 0.27 A at 250 V (Q300).
The ambient air temperature for operation is -25 to 70 °C.
It can reach Category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, PL = e conforming to ISO 13849-1, and SIL 3 conforming to IEC 61508.