The CUI Inc. VSBU-120C-15 is an open frame AC/DC converter delivering a nominal 15 Vdc output at up to 8 A (120 W). It accepts a universal input voltage range of 90 to 264 Vac at 47 to 63 Hz, with a maximum input current of 1.75 A at 100 Vac and 0.72 A at 240 Vac. Inrush current is limited to 37 A at 100 Vac and 88 A at 240 Vac (cold start). Active power factor correction achieves a typical value of 0.95 at 240 Vac full load.
Output ripple and noise is 150 mVp-p maximum, with typical efficiency of 78%. Line regulation is 1% maximum, load regulation 5% maximum (10-90% load at 230 Vac). Transient response recovers within 4 ms for a full load to half load step at 110 Vac. Start-up time is 3 s maximum, hold-up time 16 ms minimum at 100 Vac full load. Protections include over voltage (112-132%), over current (110-150% auto recovery), and short circuit (auto recovery). Isolation is 4242 Vdc input-to-output and 2121 Vdc input-to-earth ground.
The converter is safety approved to IEC/EN/UL 62368-1 with CE and cURus marks. EMI meets CISPR-32/EN 55032 Class B. Leakage current is 0.75 mA at 240 Vac full load. MTBF is 100,000 hours per MIL-HDBK-217F at 25°C. Operating temperature range is 0°C to 70°C with derating; storage temperature -40°C to 85°C. Humidity range is 0-95% non-condensing. Dimensions are 127.0 x 76.2 x 33.5 mm. Mounting is chassis mount with an open frame design. Intended for ITE (commercial) applications.
The input voltage range is 90 to 264 Vac.
The output is 15 Vdc at up to 8 A maximum.
The operating temperature range is 0°C to 70°C with derating.
It is approved to IEC/EN/UL 62368-1 with CE and cURus marks.
Yes, over voltage protection is set at 112 to 132% of nominal output.
Typical efficiency is 78%.