The CUI Inc. VOF-180C-36-CNF is a versatile AC-DC power supply designed for various applications. It delivers 180W of output power with a nominal output voltage of 36V and a maximum output current of 5A.
This power supply operates with a universal input voltage range of 85 to 264 Vac and features active power factor correction. It is certified to safety standards including 62368, 60335, and 61558, making it suitable for household appliances and ITE commercial equipment.
The VOF-180C-36-CNF is built with essential protections such as over voltage, over current, over temperature, and short circuit protection. It offers adjustable output via a trim POT and operates within a wide temperature range of -40°C to 70°C with derating.
Packaged in an enclosed chassis mount form factor, this power supply measures 103.4mm in length, 62.0mm in width, and 37.0mm in height. It is designed for reliable performance and safety in demanding environments.
The AC input range is 85-264Vac (47-63Hz) and the DC input range is 120-370Vdc.
The output is 36Vdc nominal, adjustable from 35.28 to 37.8Vdc, with a maximum current of 5A and power of 180W.
It includes over voltage protection (50Vdc latching), over current protection (110% hiccup auto recovery), short circuit protection (continuous hiccup auto recovery), and over temperature protection (output shutdown auto recovery).
Typical efficiency is 94% at 230Vac full load.
The operating temperature range is -40°C to 70°C with derating.
The dimensions are 103.4mm (length) x 62.0mm (width) x 37.0mm (height), or 4.07" x 2.44" x 1.46".
It is certified to UL/EN/IEC 62368-1, 60335-1, and 61558, with CE and cURus approvals.