| Category | |
| Manufacturer Name | |
| Compliance | |
| Efficiency | |
| Height | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Mounting Style | |
| Number of Outputs | |
| Operating Temperature Range | |
| Output Power | |
| Width |
The Vicor VI-RU232-CWVY is a FlatPAC autoranging AC-DC switcher designed for industrial applications. This enclosed unit features a chassis mounting style and accepts a wide input voltage range of 90 VAC to 264 VAC across two selectable bands (90-132 VAC and 180-264 VAC) with an input frequency of 47 Hz to 63 Hz.
This model provides three output channels: Channel 1 at 15 VDC, Channel 2 at 24 VDC, and Channel 3 at 15 VDC. The total output power can be 50 W, 100 W, or 150 W, with this specific model likely supporting up to 100W based on the introtext. The output is regulated, and the unit offers an isolation voltage of 4.242 kV. It operates within a temperature range of 0 C to +85 C.
With dimensions of 185.4 mm in width, 34.8 mm in height, and 234.8 mm in length, the VI-RU232-CWVY is suitable for integration into various industrial systems. It holds multiple industry approvals including CE, CSA, cTUVus, cURus, EN, FCC, IEC60950-1, and UL60950-1, indicating its compliance with relevant safety and performance standards.
90-132 VAC and 180-264 VAC at 47-63 Hz.
15 VDC, 24 VDC, and 15 VDC.
0°C to 85°C.
Chassis mount, enclosed.
80% to 90%.
4.242 kV.
3 outputs.