The VI-B30-CW is an isolated DC-DC converter module from Vicor's VI-200 family, designed for commercial ITE applications. This through-hole module provides a regulated 5V output at up to 20A, delivering 100W of power. Operating from a nominal 42V input, it achieves 90% typical efficiency.
The module is housed in a standard Full Brick package measuring 116.8 mm x 61.0 mm x 12.7 mm. It includes comprehensive protection features: overcurrent protection (OCP), overvoltage protection (OVP), overtemperature protection (OTP), and short-circuit protection (SCP). The operating temperature range is -25°C to 85°C.
This booster module is compatible with other VI-200 family converters for building higher power arrays. It is non-RoHS compliant (VI prefix) and may be used in applications not requiring RoHS exemption.
The nominal input voltage is 42 V.
It provides 5 V output at a maximum current of 20 A, delivering 100 W.
Typical efficiency is 90%.
It is in a Full Brick package with dimensions 116.8 mm x 61.0 mm x 12.7 mm and through-hole mounting.
The operating temperature range is -25°C to 85°C.
No, this part is non-RoHS compliant. The VI prefix indicates non-RoHS as per the Vicor datasheet.
The module features overcurrent protection (OCP), overtemperature protection (OTP), overvoltage protection (OVP), and short-circuit protection (SCP).