The Vicor VI-263-IU is an isolated DC-DC converter module from the VI-200 family. It delivers a nominal 24V output at 8.33A, providing 200W of power. The module operates from a nominal 300V input with a range of 200V to 400V, making it suitable for high-voltage bus applications.
With an efficiency of up to 90%, the VI-263-IU minimizes power loss and thermal stress. It includes protection features such as overcurrent (OCP), overvoltage (OVP), overtemperature (OTP), and short circuit (SCP). The operating temperature range of -40°C to 85°C allows use in demanding environments.
The module is housed in a full brick package measuring 116.8mm x 61.0mm x 12.7mm (4.60" x 2.40" x 0.50") and is designed for through-hole mounting. It is suitable for ITE (commercial) applications requiring reliable isolated power conversion.
| Qty | Low | High |
|---|---|---|
| 1+ | $1,206.87 | $1,206.87 |
| 10+ | $958.62 | $958.62 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The nominal input voltage is 300V with a range of 200V to 400V.
The output voltage is 24V at 8.33A, providing 200W of power.
It is housed in a full brick package with dimensions 116.8mm x 61.0mm x 12.7mm.
The module operates from -40°C to 85°C.
The datasheet indicates that the VI-200 series (non-RoHS) is not RoHS compliant, while the VE-200 series is RoHS compliant. The existing database lists RoHS3 compliance with low confidence. Verify with the manufacturer.
It includes overcurrent (OCP), overvoltage (OVP), overtemperature (OTP), and short circuit (SCP) protection.
Typical efficiency is 90%.