| Category | |
| Manufacturer Name | |
| Input | |
| Power | |
| Temperature |
The Vicor VE-AWW-CU is a component-level, DC-input front-end filter designed to occupy minimal board space while offering maximum protection for advanced electrical systems. This Input Attenuator Module (IAM) is part of the VI-200/VI-J00 series and is intended for use with 24, 48, and 300V DC input modules to create high-density power systems.
Key electrical specifications include an input voltage range of 18-36 VDC and a power rating of 200W. The operating temperature range spans from -55°C to +100°C, ensuring reliable performance in demanding environments. The VE-AWW-CU is RoHS3 compliant.
This filter is ideal for telecommunications and industrial power applications where space is at a premium and robust protection is required. Its design leverages Vicor's modular approach to power, offering efficiency and inherent reliability.
While specific mounting and termination details are not provided in the available data, the VE-AWW-CU is designed to integrate seamlessly into existing power architectures, benefiting from the small size and high performance of Vicor component-level converters.
The Vicor VE-AWW-CU supports an input voltage range of 18-36 VDC.
The VE-AWW-CU has a power rating of 200W.
The VE-AWW-CU operates within a temperature range of -55°C to +100°C.