The XP Power VCP15US05 is a 15W board-mount AC/DC converter delivering a regulated 5V output at 2A. It accepts a universal input of 90-264 VAC at 47-63 Hz, with a maximum input current of 0.5A at 90 VAC. The converter features a no-load input power below 0.3W and a typical efficiency of 74%.
Protection features include overvoltage (typical trip 10.0V), overload (120-280% auto recovery), and short circuit hiccup mode. It offers 4000 VAC input-to-output isolation and meets EN55032 class B conducted and radiated emissions. Safety approvals include EN60950-1, cUL60950-1, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1, EN62368-1, IEC62368-1, CE, and UKCA.
The open-frame design measures 65.0 x 38.0 x 26.9 mm and mounts via through-hole pins to a 5-DIP pattern. It operates from 0°C to +70°C with derating from 100% load at 50°C to 50% load at 70°C, cooled by natural convection. Typical applications include ITE (commercial) and medical equipment.
0°C to +70°C, with derating from 100% load at 50°C to 50% load at 70°C.
90-264 VAC at 47-63 Hz.
EN60950-1, cUL60950-1, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1, EN62368-1, IEC62368-1, CE, UKCA.
5V at 2A, with a maximum output power of 15W.
Overvoltage protection (typical 10.0V trip), overload protection (120-280% auto recovery), and short circuit protection (hiccup mode).
No minimum load is required.