| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
200 pcs
|
200 pcs | On Request | 1 | On Request | On Request | On Request | On Request | 2026-06-29 21:33:16 |
| Category | |
| Manufacturer Name | |
| Applications | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Industrial Grade | |
| Input Surge Withstand | |
| Input Voltage (Typ) | |
| Input Voltage Max | |
| Isolation Voltage (IN to Base) | |
| Isolation Voltage (IN to OUT) | |
| Isolation Voltage (OUT to Base) | |
| Length | |
| Load Regulation | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Overvoltage Turn-Off/On | |
| Power (Watts) | |
| Storage Temperature Range | |
| Type | |
| Undervoltage Turn-Off | |
| Undervoltage Turn-On | |
| Voltage | |
| Width |
The Vicor V300B5T200BL is an isolated DC-DC converter module from the 300V Mini Family. It provides a regulated 5V output at up to 40A, delivering 200W of output power. The module accepts a wide input voltage range of 180V to 375V DC, with a typical input of 300V. It features a high isolation voltage of 3000 VRMS between input and output, and 1500 VRMS input to baseplate.
Efficiency is typically 83%, with datasheet claims up to 89% under optimal conditions. The module includes overvoltage protection (OVP) and undervoltage lockout (UVLO) for reliable operation. Load regulation is ±0.4% from no load to full load. The operating temperature range is -40°C to 100°C, allowing use in demanding environments.
The module is housed in a surface mount package measuring 57.9mm x 55.9mm x 12.7mm. It is designed for ITE (commercial) applications and is suitable for distributed power architectures requiring high voltage input conversion.
| Qty | Low | High |
|---|---|---|
| 1+ | $431.05 | $431.05 |
| 10+ | $342.39 | $342.39 |
| 25+ | $312.87 | $312.87 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
180V to 375V DC.
5V at 40A, providing 200W output power.
-40°C to 100°C.
No, this part with BL pin finish (tin/lead) is not RoHS compliant. Only F or G pin options are RoHS compliant.
3000 VRMS input to output, 1500 VRMS input to baseplate, 500 VRMS output to baseplate.
Overvoltage protection (OVP) and undervoltage lockout (UVLO).
Typically 83%, with datasheet claiming up to 89%.