The Vicor V24C12C100BL2 is an isolated DC-DC converter module from the Maxi family, designed to deliver a regulated 12V output at up to 100W. It operates from a nominal 24V input with a wide 18V to 36V input range, making it suitable for systems with varying bus voltages.
Key electrical specifications include a typical efficiency of 85.8%, input-to-output isolation of 3000Vrms, and a load regulation of ±0.25% from no load to full load. The module includes overvoltage protection (OVP) and under-voltage lockout (UVLO) for reliable operation.
The converter is housed in a standard quarter brick package with dimensions of 57.9mm x 36.8mm x 15.7mm and features through-hole mounting. It is rated for an operating temperature range of -20°C to 100°C.
| Qty | Low | High |
|---|---|---|
| 1+ | $374.43 | $374.43 |
| 10+ | $297.42 | $297.42 |
| 25+ | $271.77 | $271.77 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The V24C12C100BL2 provides a nominal 12V output at 100W.
The input voltage range is 18V to 36V DC, with a nominal input of 24V.
It is a quarter brick package with through-hole mounting.
The operating temperature range is -20°C to 100°C.
RoHS compliance is unverified for this specific part number; the datasheet notes RoHS compliance with F or G pin options.