TY-145P The Triad Magnetics TY-145P is an audio transformer designed for line matching, telephone coupling, and other audio applications. It operates within a frequency range of 200 Hz to 15,000 Hz.
Mfr Part #:

TY-145P

Available from 1 distributors
Mfr Name: N-A
N-A
The Triad Magnetics TY-145P is an audio transformer designed for line matching, telephone coupling, and other audio applications. It operates within a frequency range of 200 Hz to 15,000 Hz.
✓ Total Stock: 394 pcs

TY-145P Available from 1 distributor

✓ Authorised
✓ Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
394 pcs
394 pcs On Request 1 On Request On Request N/A On Request On Request

TY-145P Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name

TY-145P Description

Short technical summary and product information.

The Triad Magnetics TY-145P is an audio transformer suitable for a broad application spectrum in the audio industry. It operates in the 200 Hz to 15,000 Hz range and is used in line matching, telephone coupling, pulse trigger, driver, interstage, output, isolation, and input applications.

 

Key electrical specifications include a primary impedance of 600Ω CT with a 600Ω load and a secondary impedance of 600Ω CT. It offers an output power of 100mW and a frequency response of +2dB from 200 to 15,000 Hz. The transformer also features a longitudinal balance greater than 45dB, an insertion loss of less than 1.5dB at 1K Hz, and a return loss greater than 26dB. Total harmonic distortion is less than 0.5% between 275Hz and 3.5KHz.

 

This transformer has a primary DCR of 44Ω nominal and a secondary DCR of 58Ω nominal. The turns ratio is 1:1, and it has a dielectric strength of 1500V Pri to Sec to Core. The operating temperature range is 0º C to 105º C.

 

The TY-145P features a bobbin with plug-in terminals spaced for fixed mounting centers, designed for through-hole mounting. The pins are a rugged .042” square. The overall dimensions are detailed in the datasheet, with a weight of 0.51 oz.

TY-145P Quick Information

Product Type: Audio Transformer
Series: TY-145P
Canonical Name: TY-145P Audio Transformer
Subcategory: Audio Transformer

TY-145P Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

TY-145P Features

  • Audio transformer for broad applications.
  • Operates 200 Hz to 15,000 Hz frequency range.
  • 600:600 CT impedance with 100mW output.
  • Low insertion loss and high return loss.
  • Through hole mounting with plug-in terminals.

TY-145P Applications

  • Suitable for line matching applications.
  • Used for telephone coupling circuits.
  • Applicable for pulse trigger functions.
  • Designed for driver and interstage use.
  • Ideal for isolation and input applications.

TY-145P FAQs

7 frequently asked questions generated from this part’s specifications.
What is the mounting type of the TY-145P?

Through Hole.

What is the operating temperature range?

0°C to 105°C.

What is the dielectric strength?

1500V between primary, secondary, and core.

What is the turns ratio?

1:1.

What is the frequency response?

±2dB from 200Hz to 15,000Hz.

What is the insertion loss?

Less than 1.5dB at 1kHz.

What is the primary impedance?

600Ω CT with 600Ω load.