| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
4 pcs
|
4 pcs | On Request | 1 | On Request | On Request | 847 | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Lead Style | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Tape & Reel | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Traco Power TEN 15-4810WI is a 10W isolated DC DC converter from the TEN 15WI series. It provides a regulated 3.3V output at up to 3A from a wide 4:1 input voltage range of 18 to 75VDC (48V nominal).
Key electrical specifications include a typical efficiency of 78%, line regulation of 0.5% max, load regulation of 1% max, and ripple and noise of 80 mVpk-pk max. The converter offers 1500VDC input-to-output isolation and includes features such as remote on/off control and indefinite short circuit protection with automatic recovery.
The module is housed in a 6-DIP through-hole package measuring 50.8 x 25.4 x 10.2 mm. It operates over a -40°C to +85°C temperature range (with derating above 60°C) and is designed for ITE (commercial) applications. The built-in filter meets EN 55022 Class A and FCC Part 15 Level A conducted noise limits without external components.
| Qty | Low | High |
|---|---|---|
| 1+ | $71.53 | $71.53 |
| 10+ | $61.48 | $61.48 |
| 20+ | $60.16 | $60.16 |
| 50+ | $59.19 | $59.19 |
| 100+ | $58.22 | $58.22 |
| 200+ | $55.20 | $55.20 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The output voltage is 3.3 VDC nominal.
The input voltage range is 18 to 75 VDC (48 VDC nominal).
The operating temperature range is -40°C to +85°C (with derating above 60°C).
Yes, it is RoHS3 compliant and lead free.
The package is a 6-DIP Module, 5 Leads, through hole mounting.
Yes, it has indefinite short circuit protection with automatic recovery.
The isolation voltage is 1500 VDC minimum (60 sec test).