| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
9 pcs
|
9 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Tape & Reel | |
| Type | |
| Voltage | |
| Width |
The Traco Power TDL 2-4812 is a 2-watt isolated DC-DC converter from the TDL 2 series, designed for commercial ITE applications. It accepts a nominal 48V input with a wide 2:1 range of 36 to 75 VDC and delivers a regulated 12V output at up to 167 mA.
Key electrical specifications include an efficiency of 85% typical, line regulation of 0.2% max, load regulation of 1% max, and a voltage set accuracy of ±1.5% max. The converter provides 1500 VDC input-to-output isolation and includes short circuit protection with current limitation. Output ripple and noise is 70 mVp-p typical.
The converter is housed in a compact 7-DIP module with 4 leads, measuring 14.0 x 14.0 x 8.0 mm (0.55 x 0.55 x 0.31 inches). It supports through-hole mounting and operates over a temperature range of -40°C to +70°C. No minimum load is required for operation.
| Qty | Low | High |
|---|---|---|
| 1+ | $20.10 | $20.10 |
| 10+ | $18.42 | $18.42 |
| 20+ | $18.02 | $18.02 |
| 50+ | $17.73 | $17.73 |
| 100+ | $17.44 | $17.44 |
| 200+ | $17.07 | $17.07 |
| 500+ | $16.79 | $16.79 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The input voltage range is 36 to 75 VDC, with a nominal input of 48 VDC.
It provides a single 12 VDC output at a maximum current of 167 mA, with a total output power of 2 W.
The input-to-output isolation voltage is 1500 VDC.
The operating temperature range is -40°C to +70°C.
It uses a 7-DIP Module with 4 leads, measuring 14.0 x 14.0 x 8.0 mm, for through-hole mounting.
No, the TDL 2-4812 requires no minimum load for operation.
It includes short circuit protection with current limitation at 180% of nominal output current.