| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
3,000 pcs
|
3000 pcs | On Request | 1 | On Request | On Request | On Request | On Request | 2026-02-16 21:33:16 | |
|
1,619 pcs
|
1619 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
1,055 pcs
|
1055 pcs | On Request | 1 | On Request | On Request | 1710+ | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Data Rate | |
| Junction Temperature | |
| Lead Spacing | |
| Mounting Type | |
| Number of Drivers | |
| Operating Temperature | |
| Protocol | |
| Supplier Device Package | |
| Type | |
| Voltage |
The TCAN1042HDR from Texas Instruments is a fault-protected CAN transceiver designed for robust communication in demanding environments. It meets ISO 11898-2:2016 and ISO 11898-5:2007 physical layer standards and supports both classic CAN and CAN FD up to 5 Mbps.
Key electrical features include a wide operating voltage range of 4.5V to 5.5V, symmetrical propagation delays for enhanced timing margin, and ideal passive behavior when unpowered. Protection features include ±16kV HBM ESD protection, ±15kV IEC ESD protection, and ±70V bus fault protection. The device operates reliably across a junction temperature range of -55°C to 150°C.
Packaged in an 8-pin SOIC, the TCAN1042HDR is suitable for surface mount applications. Its design ensures glitch-free operation during power up/down and provides high impedance on bus and logic terminals when unpowered, making it ideal for various automotive and industrial applications requiring reliable CAN communication.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.75 | $0.75 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The operating voltage range is 4.5V to 5.5V.
It is available in an 8-SOIC package.
The operating temperature range is -55°C to 125°C.
Yes, it supports classic CAN and CAN FD up to 5 Mbps.
It features ±16kV HBM ESD protection and ±15kV IEC ESD protection.
The bus fault protection is ±70V.