The Schurter TA45-ABFYFJ12C0-AZM10 is a thermal circuit breaker from the TA45-2R series, offering 1 or 2 pole thermal overload protection. This specific model is a 2-pole unit with rocker actuation and a current rating of 1.2A.
Key electrical specifications include a rated voltage of 240 VAC and 60 VDC, with a conditional short circuit capacity of 1 kA at 240 VAC. The breaker is designed for a mechanical lifetime of 50,000 switching cycles and features positively trip-free release.
This circuit breaker is suitable for applications such as power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It has a panel mount, snap-in mounting type and a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover.
The operating temperature range is -10 °C to 55 °C. Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 1.2A.
It features rocker actuation.
The allowable operation temperature is -10 °C to 55 °C.
The degree of protection is IP40 on the front side, and IP54 with a factory-mounted protection cover.