| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFXRJ14C0-AZM10 is a 2-pole thermal circuit breaker designed for equipment protection. It features a rocker actuation type and a panel mount, snap-in mounting style.
Key electrical specifications include a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. The conditional short circuit capacity is 1 kA AC, and the short circuit capacity Icn is up to 300A AC. The breaker has a mechanical lifetime of 50,000 switching cycles.
Environmental and mechanical data includes an operating temperature range of -10 °C to 55 °C, a degree of protection of IP40, and vibration resistance up to 10 G. The tripping type is thermal.
This circuit breaker is suitable for applications such as power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 1.4A.
This circuit breaker has 2 poles.
It uses rocker actuation.
The allowable operating temperature is -10 °C to 55 °C.