| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFXR140C0-AZM14 is a thermal circuit breaker from the TA45-2R series. It is designed for equipment protection with a 2-pole configuration and rocker actuation.
The circuit breaker has a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC. The current rating is 14A, with a rated current range of 0.05 - 20 A AC. It offers a conditional short circuit capacity of 1 kA at 240V AC and a short circuit capacity Icn of 300A at 3A/240VAC.
Environmental specifications include a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. The operating temperature range is -10 °C to 55 °C. Mechanical lifetime is rated for 50,000 switching cycles.
This component is suitable for panel mounting with a snap-in mechanism. It is approved by CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC.
The current rating is 14A.
The device has a degree of protection of IP40, upgradeable to IP54 with a cover.
The tripping type is thermal.
It complies with CSA C22.2 No 235, IEC60934, GB17701, UL1077.