| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFXKJ14C0-AZM10 is a thermal circuit breaker from the TA45-2R series, designed for reliable overload protection. This 2-pole device operates at up to 240 VAC and has a rated current of 1.4A.
Featuring a rocker actuation type and a snap-in panel mount design, this circuit breaker offers convenience in installation. It provides thermal tripping and has a mechanical lifetime of 50,000 switching cycles. The device is rated for an operating temperature range of -10 °C to 55 °C.
Key electrical specifications include a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC. The circuit breaker meets IEC 60934 standards for short circuit capacity. It is suitable for applications requiring robust circuit protection.
Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077, indicating compliance with various safety standards. The degree of protection is IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The rated current range is 0.05 - 20 A AC, with a specific rating of 1.4A for this model.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
It uses a rocker actuation type.
The degree of protection on the front side is IP40, which can be IP54 with a factory-mounted protection cover.