| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFXK150C0-AZM02 is a thermal circuit breaker from the TA45-2R series, offering 2-pole thermal overload protection. It is designed for panel mounting and features a snap-in installation method. This breaker has a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC, with a current rating range of 0.05 to 20 A. The actuation type is a rocker, and it is not illuminated.
Key technical specifications include a conditional short circuit capacity of 1 kA (AC 240V) and a short circuit capacity (Icn) of 300A at 240 VAC for currents 3A and above. It offers a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. The dielectric strength is 4 kVAC, and insulation resistance is greater than 100 MΩ at 500 VDC.
Mechanical lifetime is rated at 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C, with a similar storage temperature range. Environmental resistance includes vibration resistance up to 10 G @ 60 - 500 Hz and shock resistance of 30 G / 18 ms. The tripping type is thermal.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. It holds approvals from CSA, IEC, GB, and UL.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage AC is 240 VAC and the rated voltage DC is 60 VDC.
It supports a current range from 0.05 to 20 A.
The tripping type is thermal.
It uses panel mount, snap-in mounting.
The degree of protection is IP40, upgradeable to IP54 with cover.
It complies with CSA C22.2 No 235, IEC60934, GB17701, and UL1077.