| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFWFJ09C0-AZM12 is a 2-pole thermal circuit breaker from the TA45 series. It offers thermal overload protection with a positively trip-free release mechanism. The breaker is designed for panel mounting with a snap-in version and features a rocker actuation type.
Key electrical specifications include a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. The conditional short circuit capacity is 1 kA at 240 VAC. The device has a mechanical lifetime of 50,000 switching cycles.
Environmental considerations include a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. The operating temperature range is -10 °C to 55 °C.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, construction equipment, and cleaning equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 900mA.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
It uses a rocker actuation type.