| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45 series thermal circuit breaker, part number TA45-ABFRTJ09C0-AZM01, offers 2-pole thermal overload protection. It is designed for panel mounting and features a snap-in version for easy installation. The actuation type is a rocker, and it is not illuminated.
Key electrical specifications include a rated voltage of 240 VAC and a rated current range of 0.05 - 20 A, with this specific unit rated at 900mA. The breaker has a conditional short circuit capacity of 1 kA (AC 240V) and a short circuit capacity Icn of 300A at 240 VAC for currents 3A and above. It meets IEC 60934 standards.
Environmental and mechanical specifications include a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. The operating temperature range is -10 °C to 55 °C. Mechanical lifetime is rated at 50,000 switching cycles.
Applications for this type of circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
It supports a current range from 0.05 to 20 A.
The short circuit capacity (Icn) is 300A at specified conditions.
It has an IP40 degree of protection, IP54 with cover.
The dielectric strength is 4 kVAC.
It is rated for 50,000 switching cycles mechanically and electrically.