| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFRH140C0-AZM02 is a thermal circuit breaker from the TA45-2R series, featuring a 2-pole configuration. It is designed for panel mounting and utilizes a snap-in installation method.
This circuit breaker has a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC. The AC current rating range is from 0.05 to 20 A, with this specific model rated at 14A. It offers a conditional short circuit capacity of 1 kA at AC 240 V and a short circuit capacity Icn of 300A at In ≥ 3 A/ 240 VAC.
Key technical specifications include a dielectric strength of 4 kVAC, insulation resistance greater than 100 MΩ at 500 VDC, and a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C. The degree of protection for the front side is IP40.
Applications for this type of circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. It is approved by CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 14A.
The rated AC voltage is 240 VAC.
It has 2 poles.
It uses a rocker actuation type.
The allowable operation temperature is -10 °C to 55 °C.