This Schurter Inc. TA45-ABFRF120C0-AZM01 is a thermal circuit breaker from the TA45 series, offering 2-pole protection. It is rated for 12A and operates at up to 240 VAC or 60 VDC.
The breaker features a rocker actuation type and a panel mount, snap-in design for easy installation. It provides thermal overload protection with a positively trip-free release mechanism. The device has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10 °C to 55 °C.
Key technical data includes a conditional short circuit capacity of 1 kA at 240 VAC and various Icn ratings depending on current and voltage conditions. It also offers a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It is approved by CSA, IEC, GB, and UL standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 12A.
This circuit breaker has 2 poles.
The allowable operation temperature is from -10 °C to 55 °C.
It uses a rocker actuation type.