The Schurter Inc. TA45-ABFRF080C0-AZM10 is a 2-pole thermal circuit breaker from the TA45-2R series. It is designed for panel mounting with a snap-in mechanism and features rocker actuation. This circuit breaker has a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC, with a rated current range of 0.05 to 20 A. The tripping type is thermal, and it has a mechanical lifetime of 50,000 switching cycles.
Key electrical specifications include a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity (Icn) of 300A at 240 VAC for currents 3A and above. It offers a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC. The operating temperature range is -10 °C to 55 °C.
Environmental compliance includes RoHS3 compliance and an MSL of 1. The degree of protection is IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. Applications for this series include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 8A.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
It uses rocker actuation.