| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFGSJ28C0-AZM14 is a 2-pole thermal circuit breaker with a rocker actuation type. It is designed for panel mounting with a snap-in mechanism.
This circuit breaker features a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. The specific current rating for this model is 2.8A. It has a conditional short circuit capacity of 1 kA at AC 240 V and a short circuit capacity (Icn) of 300A at 240 VAC.
Key electrical specifications include a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC. The mechanical lifetime is rated for 50,000 switching cycles, with AC and DC lifetimes also at 50,000 cycles at 1x Ir. Overload protection is provided with a minimum of 40 trips at 6x Ir for AC and 4x Ir for DC.
Environmental and thermal specifications include an operating temperature range of -10 °C to 55 °C and a storage temperature range of -10 °C to 55 °C. It offers a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. Mechanical resistance is supported by vibration resistance specifications and shock resistance of 30 G / 18 ms.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 2.8A.
It has 2 poles.
The operating temperature range is -10 °C to 55 °C.
It uses a snap-in panel mount.