| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter TA45-2R series thermal circuit breaker, part number TA45-ABFGSJ18C0-AZM01, provides reliable thermal overload protection for 1 or 2 pole applications. It features a Rocker actuation type and is designed for panel mounting with a snap-in mechanism.
The circuit breaker has a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC, with a rated current range of 0.05 to 20 A AC. It offers a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity (Icn) of up to 300A at 240 VAC. The device is protected to IP40 on the front side, or IP54 with a factory-mounted protection cover.
Mechanical specifications include a lifetime of 50,000 switching cycles and overload capabilities of at least 40 trips at 6x Ir for AC and 4x Ir for DC. The operating temperature range is -10 °C to 55 °C. Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated AC voltage is 240 VAC and the rated DC voltage is 60 VDC.
The current rating is 1.8A.
This circuit breaker has 2 poles.
It uses Rocker actuation.
The allowable operation temperature is -10 °C to 55 °C.