| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-2R series circuit breaker offers reliable thermal overload protection. It is a 2-pole device with a rocker actuation type and a snap-in mounting style, suitable for panel integration.
The breaker is rated for 15A at 240V AC and 60V DC, with a conditional short circuit capacity of 1 kA at 240V AC. It meets various approval standards including CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
Key electrical and mechanical specifications include a dielectric strength of 4 kVAC, insulation resistance greater than 100 MΩ at 500 VDC, and a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C.
Environmental compliance includes RoHS3 compliance, MSL 1, and REACH unaffected status. The degree of protection for the front side is IP40, which can be increased to IP54 with a factory-mounted protection cover.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 15A.
The device has an IP54 degree of protection with a factory-mounted cover.
It supports 50,000 switching cycles.
It complies with CSA C22.2 No 235, IEC60934, GB17701, and UL1077.