| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFGM075C0-AZM02 is a thermal circuit breaker from the TA45-2R series, featuring a 2-pole configuration and a rocker actuation type. It is designed for panel mounting with a snap-in mechanism.
This circuit breaker has a rated current of 7.5A and can operate at up to 240 VAC or 60 VDC. It offers a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity (Icn) of 300A at 240 VAC for currents 3A or higher. The device provides thermal overload protection and has a positively trip-free release.
Key technical specifications include a dielectric strength of 4 kVAC, insulation resistance greater than 100 MΩ at 500 VDC, and a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C. It meets IP40 degree of protection on the front side, or IP54 with a factory-mounted protection cover.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It is approved by CSA, IEC, GB, and UL standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 7.5A.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
Approval agencies include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.