| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter TA45-ABFGM030C0-AZM03 is a 2-pole thermal circuit breaker from the TA45 series, designed for reliable equipment protection. This breaker offers a rated voltage of 240 VAC and a current rating range of 0.05 to 20 A, with this specific model rated at 3A.
Key technical specifications include a conditional short circuit capacity of 1 kA (AC 240V) and a short circuit capacity Icn of 300A. It provides a degree of protection rated IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. The breaker has a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC.
Designed for mechanical robustness, it boasts a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C. Actuation is via a Rocker mechanism, and the mounting type is Panel Mount, Snap-In. Applications include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077, indicating compliance with relevant safety standards for industrial environments.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 3A.
It features Rocker actuation.
The degree of protection is IP40 on the front side, and IP54 with a factory-mounted protection cover.
The allowable operation temperature is -10 °C to 55 °C.