| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFGL090C0-AZM14 is a thermal circuit breaker from the TA45-2R series. It is designed for equipment protection and offers 1 or 2 pole thermal overload protection with a positively trip-free release.
Key electrical specifications include a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 - 20 A. This specific model has a current rating of 1.1A. The conditional short circuit capacity is 1 kA at 240 VAC, and the rated short circuit capacity is 300A at 240 VAC (for In ≥ 3A) and 120A at 48 VDC (for In ≥ 3A).
The circuit breaker features a rocker actuation type and a snap-in mounting style, suitable for panel mounting. It has a mechanical lifetime of 50,000 switching cycles and overload capabilities specified for AC and DC operation. The operating temperature range is -10 °C to 55 °C.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 1.1A.
It features a rocker actuation type.
The allowable operation temperature is -10 °C to 55 °C.
Yes, it is RoHS3 Compliant.