The Schurter Inc. TA45-ABFGLJ11C0-AZM02 is a 2-pole thermal circuit breaker from the TA45 series, suitable for various industrial applications. It offers a rated voltage of 240 VAC and a rated current range of 0.05 - 20 A, with this specific unit rated at 1.1A.
This circuit breaker features a thermal tripping mechanism and a rocker actuation type. It is designed for panel mounting with a snap-in version. The device has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10 °C to 55 °C.
Key electrical specifications include a conditional short circuit capacity of 1 kA (AC 240V) and a short circuit capacity (Icn) of 300A at 240 VAC for currents 3A and above. It also boasts a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC.
Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077. The degree of protection on the front side is IP40. This component is designed for applications such as power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The rated current range AC is 0.05 - 20 A, and this specific unit is rated at 1.1A.
This circuit breaker has 2 poles.
It uses a rocker actuation type.
The allowable operation temperature is -10 °C to 55 °C.