| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFGLJ10C0-AZM13 is a thermal circuit breaker designed for equipment protection. It operates with a rated voltage of 240 VAC and 60 VDC, and has a rated current range of 0.05 to 20 A, with this specific model rated at 1A.
The breaker features a positively trip-free release mechanism and Rocker actuation. It is a 2-pole unit with non-illuminated Rocker. The mounting type is Panel Mount, Snap-In, suitable for various industrial applications.
Key technical data includes a conditional short circuit capacity of 1 kA at 240V AC and a short circuit capacity (Icn) that varies based on current rating. It offers a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. The dielectric strength is 4 kVAC and insulation resistance is greater than 100 MΩ at 500 VDC.
Mechanical lifetime is rated at 50,000 switching cycles, with AC and DC lifetimes also at 50,000 cycles at 1x Ir. Overload performance is specified as a minimum of 40 trips at 6x Ir for AC and 4x Ir for DC. The operating temperature range is -10 °C to 55 °C, with storage temperature also within this range. Vibration resistance is tested to IEC 60068-2-6, and shock resistance to IEC 60068-2-27.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 1A.
It features Rocker actuation.
The allowable operation temperature is -10 °C to 55 °C.
It is RoHS3 Compliant.
The MSL is 1 Unlimited.