| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
The Schurter TA45-ABFGL200C0 is a 2-pole thermal circuit breaker designed for equipment protection. It features rocker actuation and a snap-in mounting type for easy installation.
This circuit breaker has a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC. The AC current rating ranges from 0.05 A to 20 A. It offers a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity of 300A at 240 VAC for currents 3A or higher.
Key specifications include a dielectric strength of 4 kVAC, insulation resistance greater than 100 MΩ at 500 VDC, and a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C. The degree of protection for the front side is IP40, which can be increased to IP54 with a factory-mounted protection cover.
Applications for this thermal circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The TA45-ABFGL200C0 is a 2-pole thermal circuit breaker from Schurter with rocker actuation, designed for panel mounting and snap-in installation.
This circuit breaker is rated for 240 VAC and 60 VDC, with a current rating range of 0.05A to 20A.
The allowable operating temperature for the TA45-ABFGL200C0 is -10 °C to 55 °C.
The RoHS status is RoHS3 Compliant.