| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter TA45-ABFGKJ10C0-AZM03 is a 2-pole thermal circuit breaker from the TA45-2R series. It offers thermal overload protection with a positively trip-free release mechanism. This breaker is designed for panel mounting with a snap-in version and features a rocker actuation type.
Key electrical specifications include a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC. The AC current rating range is from 0.05 A to 20 A. It has a conditional short circuit capacity of 1 kA at 240 VAC and an Icn of 300A at 240 VAC for currents 3A and above.
Environmental and mechanical specifications include a front-side degree of protection of IP40, which can be increased to IP54 with a factory-mounted protection cover. The operating temperature range is -10 °C to 55 °C. Mechanical lifetime is rated at 50,000 switching cycles.
This circuit breaker is suitable for various applications including power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current range is from 0.05 to 20 A.
The device has an IP40 degree of protection on the front side and IP54 with a factory-mounted cover.
It has a mechanical lifetime of 50,000 switching cycles.
It complies with CSA C22.2 No 235, IEC60934, GB17701, UL1077.