| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFGK180C0-AZM03 is a 2-pole thermal circuit breaker designed for equipment protection. It operates with a rated voltage of 240 VAC and 60 VDC, and has a rated current range of 0.05 to 20 A, with a specific current rating of 18A for this model.
The breaker offers a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity Icn of 300A at 240 VAC for currents 3A and above. It features a thermal tripping type and a rocker actuation. The degree of protection is IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover.
Mechanical specifications include a lifetime of 50,000 switching cycles and overload capabilities of at least 40 trips at 6x Ir for AC and 4x Ir for DC. The operating temperature range is -10 °C to 55 °C. Mounting is via a snap-in panel mount design. Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 18A.
It uses a thermal tripping type.
The allowable operating temperature is -10 °C to 55 °C.
It is RoHS3 Compliant.
The MSL is 1 Unlimited.