| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
This Schurter Inc. TA45-ABFGK060C0-AZM12 is a 2-pole thermal circuit breaker with a 6A current rating and a 240 VAC voltage rating. It is designed for panel mounting with a snap-in mechanism.
The breaker offers thermal tripping and a rocker actuation type. It has a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity of up to 300A at 240 VAC. The operating temperature range is -10 °C to 55 °C.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It meets various approval standards including CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The rated current range is 0.05 A to 20 A AC, and this specific model is rated at 6A.
The allowable operation temperature is from -10 °C to 55 °C.
It features a rocker actuation type.
This circuit breaker has 2 poles.