This Schurter Inc. TA45-ABFGK060C0-AZM11 is a 2-pole thermal circuit breaker from the TA45-2R series, suitable for various industrial applications. It offers thermal overload protection with a positively trip-free release mechanism.
The circuit breaker has a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. It provides a conditional short circuit capacity of 1 kA at 240 VAC. The device is designed for panel mounting and features a snap-in installation type. It has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10 °C to 55 °C.
Key technical data includes a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC. The degree of protection is IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover. Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. It features a rocker actuation type and is non-illuminated.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 6A.
This circuit breaker has 2 poles.
It uses rocker actuation.
The allowable operation temperature is from -10 °C to 55 °C.
The degree of protection for the front side is IP40.