| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFBF160C0-AZM01 is a 2-pole thermal circuit breaker suitable for various industrial applications. It features a rocker actuation type and a snap-in panel mount design for easy installation.
Key electrical specifications include a rated voltage of 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. The breaker has a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity (Icn) of up to 300A. It offers a mechanical lifetime of 50,000 switching cycles.
Environmental and mechanical data includes an operating temperature range of -10 °C to 55 °C and a degree of protection of IP40 on the front side. The breaker is built for reliability with a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It is approved by CSA, IEC, GB, and UL standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 16A.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
It uses a rocker actuation type.
The mounting type is Panel Mount, Snap-In.