| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter TA45-2R series circuit breaker is a thermal type designed for equipment protection. It features a 2-pole configuration and a rocker actuation type, suitable for panel mount and snap-in installations.
The breaker is rated for 240 VAC and 60 VDC, with a rated current range of 0.05 to 20 A. It has a conditional short circuit capacity of 1 kA at 240V AC and a short circuit capacity of 300A at 240V AC for currents 3A and above. The device offers a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover.
Mechanical specifications include a lifetime of 50,000 switching cycles and overload capabilities of at least 40 trips at 6x Ir for AC and 4x Ir for DC. The operating temperature range is -10 °C to 55 °C. Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 4A.
It features rocker actuation.
The allowable operation temperature is -10 °C to 55 °C.
Yes, it is RoHS3 Compliant.