The CUI Inc. SWI5-5-E-P6 is an AC-DC power supply designed for wall mounting, featuring a Class II construction. It operates with a universal input voltage range of 90 to 264 Vac and a frequency range of 47 to 63 Hz, delivering a stable 5V output at up to 1.0A, for a maximum power of 5.0W.
This adapter is designed for ITE (Commercial) applications and meets efficiency standards including Level VI and CoC Tier 2 compliance. It incorporates over-current, over-voltage, and short-circuit protections for enhanced safety. The unit has an ultra-compact case and a no-load power consumption of less than 0.075W.
Key electrical specifications include a line and load regulation of ±5%, a start-up time of 3 seconds, and a hold-up time of 5 ms. The operating temperature range is from 0°C to 40°C. The output connector is a standard barrel plug with dimensions of 2.5mm I.D. x 5.5mm O.D. x 9.5mm, and the input connector is CEE 7/16, suitable for European outlets. The cord length is 1.50m (59").
Safety approvals include CB Scheme and IEC certification to 62368-1 standards. The MTBF is rated at 50,000 hours. Environmental compliance includes RoHS3 compliance and an MSL of 1.
The input voltage range is 90 to 264 Vac at 47 to 63 Hz.
Output voltage is 5 Vdc and maximum output current is 1.0 A.
Operating temperature range is 0°C to 40°C.
It meets Level VI and CoC Tier 2 efficiency standards with an average efficiency of 74.9%.
Dimensions are 22.6mm x 36.0mm x 65.6mm (0.89" x 1.42" x 2.58").
Over voltage protection at 6.5 Vdc minimum, over current protection at 1.8 A minimum, and short circuit protection with auto recovery.
It carries CB Scheme and IEC approvals per standards 60950-1 and 62368-1.