This CUI Inc. SMI6B series AC-DC power supply, model SMI6B-9-V-P6, is designed for wall-mount applications requiring a reliable 9V output. It delivers a maximum output current of 660mA and a total output power of 5.94W.
The adapter features a universal input voltage range of 90 to 264 Vac and operates across a frequency range of 47 to 63 Hz. It meets DoE Level VI and CoC Tier 2 efficiency standards, ensuring energy-conscious operation with a typical efficiency of 79.6% at full load and a low no-load power consumption of 0.06W.
Designed for versatility, it includes interchangeable AC blades and a compact form factor measuring 47.0mm x 34.5mm x 26.4mm. The unit offers over-voltage and short-circuit protections for enhanced safety. It is certified to UL/EN/IEC 62368-1 and carries multiple safety approvals including UL/cUL, GS, RCM, CCC, and PSE.
Key electrical specifications include a maximum ripple and noise of 300mVp-p, line regulation of ±5%, and load regulation of ±5%. The operating temperature range is from 0°C to 40°C, making it suitable for various ITE (Commercial) applications.
90 to 264 Vac.
9 Vdc at up to 660 mA, with maximum output power of 5.94 W.
0°C to 40°C.
Average efficiency is 79.6%, measured at 25%, 50%, 75%, and 100% load.
Over current protection at 0.8 A and short circuit protection with output shutdown and auto recovery.
Barrel plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm, positive center polarity.
CB Scheme, CCC, CSA, FCC, IEC, PSE, RCM, and UL.