| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
15,600 pcs
|
15600 pcs | On Request | 1 | On Request | On Request | 2012+ | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Capacitance | |
| Fail Short | |
| Impulse Discharge Current (8 | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| SVHC Present | |
| Voltage |
The Littelfuse Inc. SL1021A230R is a Gas Discharge Tube Arrester (GDT) designed for circuit protection. It offers a nominal breakdown voltage of 230V and can handle an impulse discharge current of 10kA (8/20μs pulse).
This GDT is suitable for protecting sensitive telecom and networking equipment from lightning strikes and switching operations. It features ultra-low capacitance, typically 1.5pF or less, and optimized internal geometry for low insertion loss at high frequencies, making it ideal for broadband and high-speed transmission equipment.
The device has a 3-pole configuration and is designed for through-hole mounting. Its operating temperature range is -40°C to +90°C. The SL1021A/B series is RoHS compliant.
Applications include broadband equipment, ADSL, XDSL, satellite and CATV equipment, splitters, general telecom equipment, network interfaces, telephone line cards, repeaters, modems, and line test equipment.
230 V.
10 kA (8/20 μs pulse).
3 poles.
-40 to +90°C.
Axial Cylinder, 3 Lead (Radial Bend), Through Hole.
1.5 pF or less at 1 MHz.
Glow voltage 60-200 V, arc voltage 10-35 V.