| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
1,149 pcs
|
1149 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Conflict Minerals | |
| Current | |
| Failure Rate | |
| Fault Protection | |
| Features | |
| Input Type | |
| Input Voltage | |
| Interface | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Configuration | |
| Output Type | |
| Package / Case | |
| Ratio | |
| Rds On (Typ) | |
| SVHC Present | |
| Supplier Device Package | |
| Supply Current | |
| Switch Type | |
| Tape & Reel | |
| Turn Off Time | |
| Voltage |
The Vishay Dale SIP32462DB-T2-GE1 is an integrated high-side load switch featuring slew rate control. It operates over an input voltage range of 1.2 V to 5.5 V.
Key electrical specifications include a maximum switch current of 2 A and a current limit of 1.2 A. The Rds On is typically 50 mΩ at 3 V. The device is compatible with 1.2 V to 3.3 V logic and features an On/Off interface.
This load switch is designed for applications requiring controlled power delivery. It includes features such as reverse current blocking when the switch is off. The device is available in a compact 4-WCSP (0.76x0.76) package, suitable for surface mounting.
Applications for this series include smartphones, GPS devices, tablet computers, medical equipment, industrial instrumentation, and game consoles.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.32 | $0.32 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The operating voltage range is 1.2 V to 5.5 V.
It is available in a 4-WCSP (0.76x0.76) surface-mount package.
It operates over -40°C to +85°C ambient temperature.
The maximum switch current is 2 A, with a maximum current limit of 1.2 A.
Typical on-resistance is 54 mΩ at 3 V, with a maximum of 150 mΩ.
Turn-on time is 7.5 µs typical (120 µs max) and turn-off time is 2 µs maximum.
The device includes reverse-current fault protection.